EFFECT OF BLOOD SAMPLE VOLUME WITH ANTICOAGULANT K2EDTA ON HEMATOCRIT LEVEL
Main Article Content
Abstract
Introduction: Pre-analytical stage errors contributed the most to laboratory errors (46-77.1%). Some things that include pre-analytical errors include hemolysis (53.2%), insufficient specimen volume (7.5%), unreadable handwriting (7.2%), wrong specimen, specimen has clot, vacuum error container or type of anticoagulant, specimen volume ratio and inappropriate anticoagulant. Research: aims to determine the effect of blood sample volume with K2EDTA anticoagulant on Hematocrit Levels. Methods: manual method and automatic method. Data analysis used normality test, data transformation test, Wilcoxon test using SPSS. The sampling technique used Nonprobability in the form of Purprosive sampling. This research was conducted at the Muhammadiyah IKesT Hematology Laboratory and RS. Bunda Palembang in February – March 2023. The study used EDTA blood samples from grade 2 and 3 female students DIV IKesT Muhammadiyah Palembang Medical Laboratory. Results: the average hematocrit examination with 3CC EDTA blood volume was 54.1% and 1CC EDTA blood was 42.3%. The conclusion of the study is that there is an effect of blood sample volume with K2EDTA anticoagulant on hematocrit levels. Discussion: there is an effect of blood sample volume with K2EDTA anticoagulant on hematocrit levels.
Article Details
References
Cahya, F. N. (2021). Perbandingan Jumlah Eritrosit pada Sampel Darah 3 mL, 2 mL, dan 1 mL dengan Antikoagulan K2EDTA. Jurnal Ilmiah Kesehatan Media Husada, 10(1), 59–64. https://doi.org/10.33475/jikmh.v10i1.258
Dewi, L. S., & Kusuma, D. P. (n.d.). MENGGUNAKAN EDTA KONVENSIONAL DAN VACUTAINER Comparison Of Erythrocyte Count Examination Results Using Conventional Edta And Vacutainer. 1–4.
Jiwintarum, Y., Srigede, L., & Asyhaer, R. K. (2020). Hematocrite Values With High Measurement Of Eritrosit After Centrifugation On Serum Making. Jurnal Analis Medika Biosains (JAMBS), 7(2), 112. https://doi.org/10.32807/jambs.v7i2.193
Kartikasari, N. D., Notopuro, P. B., Widodo, W., & Hernaningsih, Y. (2020). Hemoglobin, Hematocrit, Leukocyte, and Platelet Changes Due To Ultrafiltrationhemodialysis in Chronic Kidney Disease Patients. Indonesian Journal of Clinical Pathology and Medical Laboratory, 26(3), 340–343. https://doi.org/10.24293/ijcpml.v26i3.1565
Lippi, G., Von Meyer, A., Cadamuro, J., & Simundic, A. M. (2019). Blood sample quality. Diagnosis, 6(1), 25–31. https://doi.org/10.1515/dx-2018-0018
Manik, S. E., & Haposan, Y. (2021). Babul Ilmi_Jurnal Ilmiah Multi Science Kesehatan ANALISIS FAKTOR-FAKTOR FLEBOTOMI PADA PEMERIKSAAN TROMBOSIT. 13(1), 126. https://jurnal.stikes-aisyiyah-palembang.ac.id/index.php/Kep/article/view/
Meilanie, A. D. R. (2019). Different of Hematocrit Value Microhematocrit Methods and Automatic Methods in Dengue Hemorrhagic Patients With Hemoconcentration. Journal of Vocational Health Studies, 3(2), 67. https://doi.org/10.20473/jvhs.v3.i2.2019.67-71
Permana, A., Zuraida, Z., & Sindarama, S. H. (2020). Gambaran Pemeriksaan Volume Darah 1 cc Dan 3 cc Dengan Konsentrasi Antikoagulan EDTA Terhadap Kadar Hemoglobin Di Klinik Dewi Sartika. Anakes : Jurnal Ilmiah Analis Kesehatan, 6(1), 77–81. https://doi.org/10.37012/anakes.v6i1.358
Ramdhani, R., Mentari, I. N. ., & Atfal, B. (2019). Variasi Volume Sampel Darah Pada Tabung Vacutainer Edta Terhadap Pemeriksaan Darah Lengkap. Media of Medical Laboratory Science, 3(2), 80–86. http://www.lppm.poltekmfh.ac.id/index.php/mmls/article/view/203
Riba, V. C. J., Pessini, P. G. S., Chagas, C. S., Neves, D. S., Gascón, T. M., Fonseca, F. L. A., & Silva, E. B. (2020). Interference of blood storage containing K2EDTA and K3EDTA anticoagulants in the automated analysis of the hemogram. Jornal Brasileiro de Patologia e Medicina Laboratorial, 56, 1–6. https://doi.org/10.5935/1676-2444.20200037
Rosidah, & Wibowo, C. (2018). Perbedaan Antara Pemeriksaan Antikoagulan Edta Dan Heparin Terhadap Nilai Hematokrit (Hct). Jurnal Sains, 8(16), 16–21. http://journal.unigres.ac.id/index.php/Sains/article/view/800/671
Saleh, R., Dwiyana, A., & Parno. (2019). Pengaruh Variasi Waktu Centrifugasi Terhadap Hasil Pemeriksaan Hematokrit Metode Makro Pada Mahasiswa Program Studi D-Iii Analis Kesehatan. Jurnal Media Laboran, 9(2), 39–43. https://uit.e-journal.id/MedLAb/article/view/583/427
Sari, I. (2022). Flebotomy Education To Indo Health School Students in Palembang Department of Medical Laboratory Technology. Khidmah, 3(2), 320–325. https://doi.org/10.52523/khidmah.v3i2.349
Sutaji, R. (2020). Pengaruh perbedaan volume darah pada tabung vacutainer k 2 edta terhadap nilai hematokrit metode otomatis karya tulis ilmiah. D.
Syuhada, Tusy Triwahyuni, A. D. N. (2021). PERBANDINGAN INDEKS ERITROSIT PADA SAMPEL DARAH 3 mL, 2 mL, DAN 1 mL DENGAN ANTIKOAGULAN K2EDTA DI RSUD DR. H. ABDUL MOELOEK BANDAR LAMPUNG. 5, 1–7.
Syuhada, S., Aditya, A., & Candrawijaya, I. (2020). Perbedaan Hematokrit Darah Segar dan Darah Simpan (30 Hari) DI UTD RSAM Bandar Lampung. Jurnal Ilmiah Kesehatan Sandi Husada, 12(2), 646–653. https://doi.org/10.35816/jiskh.v12i2.379
Syuhada, S., Izzuddin, A., & Yudhistira, H. (2021). Perbandingan Trombosit dengan Antikoagulan K2EDTA. Jurnal Ilmiah Kesehatan Sandi Husada, 10(1), 170–176. https://doi.org/10.35816/jiskh.v10i1.575
Tominik, V. I. (2017). Dampak volume darah dalam tabung K2EDTA dengan hasil jumlah leukosit. Masker Medika, 5(Vol. 5 No. 2 (2017): Masker Medika), 1–5. https://jmm.ikestmp.ac.id/index.php/maskermedika/issue/view/1